GPIO is a general purpose I/O interface for control integration of an AHM, Avantis or dLive system and third party hardware. It offers 8 opto-coupled inputs and 8 relay outputs on Phoenix connectors, in addition to two +10V DC outputs.
Up to 8 GPIO modules can be connected to an AHM, Avantis or dLive system via Cat cable, directly or via a network switch. GPIO functions are programmed using the AHM System Manager software, dLive Surface / Director software or Avantis mixer / Director software and can be configured for a number of install and broadcast applications, including EVAC (alarm / system mute), broadcast (on air lights, fader start logic) and theatre automation (curtains, lights).
ⓘ GPIO requires dLive firmware V1.6 or higher.
Layout and connections
DC input - The unit can be powered by the supplied AC/DC adapter or alternatively via Cat5 cable when connected to a PoE source.
ⓘ Use only the power supply provided with the product (ENG Electric 6A-161WP12, A&H part code AM10314). The use of a different power supply can cause electrical or fire hazards.
- Network Reset - Resets Network settings to the default IP address 192.168.1.75 with subnet 255.255.255.0. Hold down the recessed switch whilst powering up the unit to reset.
- Network socket - PoE IEEE 802.3af-2003 compliant.
- Status LEDs – Light to confirm Power, physical connection (Lnk) and network activity (Act).
- Inputs – 8x opto-coupled inputs, switching to ground.
- Outputs – 8x relay outputs and 2x 10V DC outputs. All relay outputs are normally open by default. Output 1 can be configured to be normally closed as indicated here:
| Cut solder link LK11 on the internal PCB. Solder link LK10. |
Installation
GPIO can be used free standing or up to two units can be installed in a 1U rack space using our optional rack ear kit FULLU-RK19 which can be ordered from your A&H dealer.
STP Cat5 or higher cables are required, with a maximum cable length of 100m per connection.
ⓘ The GPIO and its network connection are for indoor use only.